Find Electric Control Valve, Flange Control Valve, Globe Control Valve on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Control valve > Pneumatic Globe Control Valve

Pneumatic Globe Control Valve

Basic Info

Model No.:  PGCV

Product Description

Model NO.: PGCV Material: Stainless Steel Sealing Form: Bellows Globe valve Application: Lining Fluorine Valve, Cryogenic Globe Valve, Plunger Type Globe Valve, Heat Preservation Globe Valve, Forged Steel Globe Valve, Oxygen Globe Valve, Bellows Globe Valve Size: Nps 1 1/2′′-12′′ Face to Face: API609/Mss Sp-68/En558 Design & Manufacture: API609/Msssp-68/En593/Awwac504 Trademark: VC or as required Origin: China Actuator: Pneumatic Structure: Through Way Globe Valve Stem Thread Position: Inside Screw Stem Globe Valve Standard: DIN, ANSI, BSW Pressure Rating: Class 150-600 End Connection: Asme B16.5/En1092 Test & Inspection: API 598/API 6D/ISO5208 Specification: CE, ISO, API HS Code: 8481804090

Name

Control valve

Pressure

150LB/300LB/600LB/900LB1500LB/2500LB

Design standard:

GB/T17213 ,IEC60534 ,GB/T4213

Face to face:

ASNI/ISA.S75.15:1987 ASNI/ISA.S75.16:1987

Flange ends:

ASME B 16.5    ASME B16.47

Inspection standard:

ISA 75.19.01,GB/T17213.4-2005,IEC60531-4:1999

 
 
Pneumatic Globe Control Valve Main Features
1. Equipped with MF or MFA series multiple springs diaphragm actuators produced by our company, with compact structure, and large output force. Positive and negative effects of the actuators are easy to transform.2. Small pressure drop loss, large capacity with high precision, and large adjustable range.
3. Large oriented coverage, resistance to shock
4. Quick replaceable valve seat, convenient maintenance.
5. Its leakage Volume satisfy the requirements of the IEC 60534-4 Class IV.
6. Adjustable range: 1:50
 Return Difference; Intrinsic Error; Dead Area; Deviation between Ends; Deviation of Nominal Stroke

Pneumatic control valve Items

Without Localizer

With Localizer

A

B

C

D

E

A

B

C

D

E

Limit of Intrinsic Error

±15

±10

±8

±6

±5

±4.0

±2.5

±2.0

±1.5

±1.0

Return Difference

10

8

6

5

3

3.0

2.5

2.0

1.5

1.0

Dead Area

8

6

5

4

3

1.0

1.0

0.8

0.6

0.4

Limit of Intrinsic Error

Air to Open

Initial Point

±6.0

±4.0

±4.0

±2.5

±2.5

±2.5

±2.5

±2.0

±1.5

±1.0

End Point

±15

±10

±8

±6

±5

Air to Close

Initial Point

±15

±10

±8

±6

±5

End Point

±6.0

±4.0

±4.0

±2.5

±2.5

Deviation of Nominal Stroke

Metallic Seal

+6

+4

+4

+2.5

+2.5

+2.5

+2.5

+2.5

+2.5

+2.5

Elastic Seal

Measured Stroke >Nominal Strike

 
 Mterial inspecifition:
 
 
 
 Aceessary Information:
 

Applications

Control flow, pressure

Body type

Globe type control valve

Actuator type

Diaphragm Pneumatic Actuator or Electric Actuator

Two fuction types

Modulating/control type, shut off/on off type

Various mediums

Water, Steam, Oil, Acid

Wide size

1/2''-20'' or larger

Many materials

   Carbon Steel/Stainless Steel,
WCB, WCC, WC6, WC9, 304SS, 316SS, Alloy , LCB ,etc

High pressure

 ANSI 150Lb-2500Lb

Signal input

Electric signal:4-20mA, Gas signal:3-15psi

Flow characteristics

Linear, Equal-percent, Quick-open

Accessories

For Pneumatic Actuator:
Mesto/Simens/YTC Positioner, Air Set, Hand Wheel,
(Explosion proof,or normal)  
For Electric Actuator:
 Hand Wheel, solenoid valve, Limit Switch,
 (Explosion proof,or normal)


Applications:
Water Pump Station
Oil Field
Gas Station
Power Station
 
Pls visit www.vcvalve.com for more information and directly contact us on details!

Contact us if you need more details on Penumatic Control Valve. We are ready to answer your questions on packaging, logistics, certification or any Other aspects about ANSI Control Valve、Electric Control Valve. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Control valve